<

欧美日韩在线精品一区二区三区激情综合,欧美日韩成人精品久久久免费看,欧美日韩国产中文精品字幕自在自线,欧美日韩激情无码专区,欧美日韩精品一区二区三区不卡,亚洲精品国产日韩无码AV永久免费网,欧美一级毛片在播放免费一区二区狠狠色丁香久久婷婷,亚洲狠狠婷婷综合久久久久图片,久久大香伊蕉在人线,狠狠色伊人久久精品综合网,篠田优,近親相姦中出し親子在线,久久久无码国产精品免费,日本精品久久久久久久影视,欧美日韩视频在线观看,推特网红冯珊珊公园任务,亚洲精品无码理论片,久久精品国产尤物奈,亚洲国产精品偷窥,欧美日韩国产色综合一二三四,欧美日韩亚洲综合一区二区三区激情在线,国产伦码精品一区二区

SZ CnAuto automation equipment Co., Ltd.

Specializing in the production of automatic\precision\high speed dispenser manufacturers

Hot Tel:

18929475867

Contact

TEL:

18929475867

深圳中制自動化設(shè)備有限公司

Email:jerry@prcrobot.net

QQ:a :

ADD:東莞市塘廈鎮(zhèn)石潭浦大逕路62號

Types of problems in the use of dispensing valves

作者:馬交易???日期:2019-08-29 15:36???瀏覽:

1. Leakage of rubber valves
 
Leakage problems usually occur after the dispensing valve closes. 95% of the cases occur because the needle caliber is too small to match.
 
復(fù)動點(diǎn)膠閥 Too small a needle can affect the flow of liquid and cause back pressure. Therefore, the dispensing valve can not accept the strength of backdraft, and will soon form dripping at the rubber mouth. When the dispensing valve is used again, too small needle will affect the function of exhaust bubbles. Rubber valves can adjust the input pressure, not too high pressure, but can drive glue, but also can be fine-tuned. After adjusting the size of the dispensing needle, we began to use the specifications of the dispensing needle to solve the problem of the rubber valve, because the size of the dispensing needle will directly affect the back pressure, so we just need to replace the larger needle.
 
The conical oblique needle produces the lowest back pressure and the smoothest flow of liquid. When the filling valve closes, the air in the liquid leaks. It is better to remove air from the fluid in advance or to use glue which is not easy to contain bubbles, or to use glue after centrifugal stirring.
 
2. The size of glue is different.
硅膠涂膠  
When the discharge of glue flow is inconsistent, it is mainly caused by unstable pressure cylinder or uneven colloid force.
 
Pneumatic valves shall be set to be 10 to 15 psi lower than the factory minimum pressure. The pressure used in the pressure tube should be above the pressure in the middle of the pressure gauge, and the pressure in the low pressure part of the pressure gauge should be avoided. The pressure of dispensing controller should be at least 60 psi to ensure the stability of the glue filling. Finally, check the coating time. If less than 15/1000 seconds, the coating will be unstable, and the longer the rubber time, the more stable the amount of rubber.
 
3. Flow velocity is too slow
 
If the flow rate is too slow, the pressure can be increased or the needle can be changed within the specification range. If the hose is too long, the excess hose can also be cut appropriately.
 
 點(diǎn)膠閥 4. Bubbles in Fluid
 
If the valve is opened too short, excessive fluid pressure may cause air to seep into the liquid. The solution is to reduce fluid pressure and use tapered oblique needles.
 
5. If the joints and pipes are blocked by glue. This situation is mainly due to excessive moisture or reuse of glue, not timely cleaning led to problems.
 
The solution to the problem of blockage of dispensing valve: the hose is thoroughly cleaned with acetone, and there is no water. It should be determined that the air pressure used is dry, and air filters need to be installed on the air pressure valve to discharge moisture from the air.